Technical Parameters
KP48-Z
Peak flow (glass rotameter)
≥12L/min
Effective flow (TSI meter)
≥6L/min
Negative pressure
≤-0.07MPa
Positive pressure
≥0.28MPa
Power
≤20W
Noise
≤72dB
Weight
≈450g
Control method
Switch control,support speed regulation
Rated voltage
12V/24V
Motor type
Brushless DC
Connector type
G1/8 internal thread (8mm quick-connect connector as standard)
Product life
≥10000h
Wear parts maintenance
If the operating pressure is ≥0.2MPa, it is recommended to replace the valve plate after 2000h and the piston plate after 2000h. If the operating pressure is <0.2MPa, it is recommended to replace the valve plate after 5000h and the piston plate after 5000h.
Applicable environment